OPTIMASS 2400
Coriolis mass flowmeter for highest capacity bulk measurement
- For gases and liquids up to 4,600 t/h; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- CT: OIML R117, MI-005, MI-002; API and AGA compliant
- Flange: DN100…400 / 4…16", max. PN160 / ASME Cl 1500
- 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®
Product variants
OPTIMASS 2400
Coriolis mass flowmeter for highest capacity bulk measurement
- For gases and liquids up to 4,600 t/h; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- CT: OIML R117, MI-005, MI-002; API and AGA compliant
- Flange: DN100…400 / 4…16", max. PN160 / ASME Cl 1500
- 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®
Product variants
Overview
The OPTIMASS 2400 is the world’s highest capacity Coriolis mass flowmeter for liquids and gases. With its twin or four straight tube design, the Coriolis meter is ideally suited for bunkering operations and custody transfer or fiscal metering in the oil and gas industry. It can also be used for any bulk mass application with many other products such as syrup, molasses or raw chemicals up to 4,600 t/h / 169,000 lb/min. The Coriolis meter features Entrained Gas Management (EGMTM) for liquid applications, maintaining operation over a wide range of gas fractions and complex flow conditions.
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
- Twin or four straight tube design
- Entrained Gas Management (EGMTM): maintains operation with air or gas entrainments in the medium
- Device commissioning, verification, diagnostics and monitoring via a secure wireless Bluetooth® connection (<20 m / 65.6 ft)
- Fast and completely digital signal processing
- High accuracy mass, density and volume flow measurement (±0.1% of MV / optional ±0.05% of MV)
- Highest OIML accuracy class of 0.3 for custody transfer (CT)
- Extensive sensor and process diagnostics (incl. NE 107)
- With integral pressure compensation for flow and density measurement
- Integrated temperature measurement
- Optimised flow splitter for low pressure loss
- Duplex steel or Super Duplex steel sensor material
- Optional PED approved secondary pressure containment up to 150 barg / 2175 psig
- Optional heat tracing (insulation, heating jacket) or purge ports
- No crosstalk: resistant to installation and process effects
- On-site verification of flowmeter with OPTICHECK service tool